FCU 1000 Series
Description
The Fluid Control Unit FCU 1000 series combines the advantages of the portable contamination measurement units FCU 2000 series with the measurement technology of the Contamination Sensor CS 1000. The FCU 1000 is a portable service unit and is designed for temporary measurement of solid particle contamination in hydraulic systems. The integrated pump and the hoses which are contained in the scope of delivery of the FCU 1000 series.
- Control circuits
- Pressure circuits
- Fluid sampling from pressureless reservoirs
Applications
- Hydraulic systems
- Service for mobile hydraulics
- Maintenance
Advantages
- Cleanliness classes ISO and SAE or NAS
- Integration of AquaSensor AS 1000 for measurement of moisture and temperature
- Applicable for hydraulic fluids up to 350 mm²/s
Technical Details
GENERAL DATA | |
Operation | intermitting (S4, according DIN EN 60034/VDE 0530) |
Self-diagnostics | continuously with error indication viastatus LED and display |
Display | LED, 6 / 4 / 4 digits, in 17 segment format |
Measured value | ISO code / SAE Class / NAS Class / Saturation level / Temperature |
Measuring range | Display from ISO code 9/8/7 (MIN) to ISO code 25/24/23 (MAX) Calibrated within the range ISO 13/11/10 … ISO 23/21/18 Saturation level 0 … 100% Temperature -25 … 100°C / -13 … 212°F |
Accuracy | +/- 1/2 ISO class in the calibrated range / ≤ 2 % Full scale max. |
Sealing material | FPM |
Ambient temperature range | 0 … +45°C / 32 … 113°F |
Storage temperature range | -40 … +80°C / -40 … 176°F |
IP class | IP50 in operation IP67 when case is closed |
Weight | ≈ 13 kg |
HYDRAULIC DATA | |
Operating pressure
with adaptor for pressure lines | IN: – 0.5 … 45 bar / -7.25 … 650 psi OUT: 0 … 0.5 bar / 0 … 7.5 psi IN: 15 … 345 bar / 217 … 5000 psi |
Maximum pressure | 345 bar / 5000 psi |
Measurement flow rate | 30 … 300 ml/min (depending on viscosity) |
Maximal suction height | 1 m |
Permissible viscosity range | 10 … 350 mm²/s 46 … 1622 Sus (for hydraulic oils up to ISO VG 68) |
Fluid temperature range | 0 … +70°C / 32 … 158°F |
ELECTRICAL DATA | |
Power supply voltage | 24 VDC ±20%, residual ripple < 10% |
Max. power / current consumption | 100 Watt / 4000 mA |
Interface | Plug connection, 5-pole, male, M12x1 and Bluetooth 1.2, Class 3 (HYDAC Sensor Interface – HSI, only) |