The LXM J1939 Control Module can be programmed as a stand-alone controller or controlled by virtually any CAN Bus master module. Bi-color LED feedback allows for in-field diagnostics and troubleshooting. With 18 configurable inputs/outputs, the LXM has the versatility to satisfy the needs of a multitude of applications.
Details
Specs
Documentation
Related Products
Model #: LXM J1939
u003culu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00221u0022u003eu003cspan style=u0022font-weight: 400;u0022u003eInputs: 18u003c/spanu003ernu003culu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00222u0022u003eu003cspan style=u0022font-weight: 400;u0022u003e4 × Voltageu003c/spanu003eu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00222u0022u003eu003cspan style=u0022font-weight: 400;u0022u003e12 × Digitalu003c/spanu003eu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00222u0022u003eu003cspan style=u0022font-weight: 400;u0022u003e2 × Frequencyu003c/spanu003eu003c/liu003ernu003c/ulu003ernu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00221u0022u003eu003cspan style=u0022font-weight: 400;u0022u003eOutputs: 18u003c/spanu003ernu003culu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00222u0022u003eu003cspan style=u0022font-weight: 400;u0022u003e8 × PWMu003c/spanu003eu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00222u0022u003eu003cspan style=u0022font-weight: 400;u0022u003e4 × Digitalu003c/spanu003eu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00222u0022u003eu003cspan style=u0022font-weight: 400;u0022u003e6 × Groundu003c/spanu003eu003c/liu003ernu003c/ulu003ernu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00221u0022u003eu003ca href=u0022https://en.wikipedia.org/wiki/IP_Codeu0022 target=u0022_blanku0022 rel=u0022noopeneru0022u003eu003cspan style=u0022font-weight: 400;u0022u003eIngress Protection: IP68u003c/spanu003eu003c/au003eu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00221u0022u003eu003cspan style=u0022font-weight: 400;u0022u003eOutput Protection: Over Load Shutdown; Open Load Detectionu003c/spanu003eu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00221u0022u003eu003cspan style=u0022font-weight: 400;u0022u003eMaximum Load: 6 ampsu003c/spanu003eu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00221u0022u003eu003cspan style=u0022font-weight: 400;u0022u003eOperating Temp: –40°– 170°Fu003c/spanu003eu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00221u0022u003eu003cspan style=u0022font-weight: 400;u0022u003eProtocol: SAE J1939u003c/spanu003eu003c/liu003ernu003c/ulu003ernu0026nbsp;rnrnu003cspan style=u0022font-weight: 400;u0022u003eOptions:u003c/spanu003ernu003culu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00221u0022u003eu003cspan style=u0022font-weight: 400;u0022u003eLDA-Tx Seriesu003c/spanu003eu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00221u0022u003eu003cspan style=u0022font-weight: 400;u0022u003eLHT Seriesu003c/spanu003eu003c/liu003ern tu003cli style=u0022font-weight: 400;u0022 aria-level=u00221u0022u003eu003cspan style=u0022font-weight: 400;u0022u003eLCM J1939 Controlleru003c/spanu003eu003c/liu003ernu003c/ulu003e
+
–
General Specifications
Weight
1 lb
Operating Temp
-40 – 170°F (-40 – 76.667°C)
Ingress Protection
IP 68
Voltage Supply
9 – 32 VDC
Current Consumption
Outputs OFF – 50 mA (12 VDC) 35 mA (24 VDC), 15 amps max.
Can Protocol
SAE J1939
+
–
Output Specifications
PWM Outputs
Number
8
Type
High Side Switching (Hydraulic Solenoids, Horns, Lights, Relays etc.)
Max Load
6 Amps per output
PWM Frequency
19 – 300 Hz
Duty Cycle Resolution
0.10%
Protection
Over Load Shutdown, Open Load Detection
Digital Outputs
Number
4
Type
High Side Switching (Hydraulic Solenoid, Horns, Lights, Relays, etc. )
Max Load
6 Amps per output
Protection
Over Load Shutdown, Open Load Detection
Ground Output
Number
6
Type
Low Side (Direct Input to ECM for Shutdown, Relay, Lamp)
Max Load
500 mA
+
–
Input Specifications
Voltage Inputs
Number
4
Signal Range
0 – 5 VDC
Max Voltage
32 VDC
Resolution
1.25 mV
Digital Inputs
Number
12
Signal Range
3 VDC
Max VoltageMax Voltage
32 VDC
Frequency Inputs
Number
2
Frequency Range
1 – 20000 Hz
Min Signal Voltage
2 VAC
+
–
User Interface
LEDs
22 Bi-Color LEDs for I/O Diagnostics
Connection
2 x Deutsch 12 Socket Mini connectors
No file found in this row.
Industries We Serve
Forestry | Utilities | Agriculture
The LCM J1939 Control Module enhances control for diesel-powered forestry machinery, utility vehicles and advanced agricultural equipment.
Concrete | Construction | Municipal
The LCM J1939 Control Module provides precise operation for construction equipment, hydraulic control systems and municipal maintenance vehicles.
Mining | Metals | Oil u0026 Gas
The LCM J1939 Control Module ensures robust control for mining machinery, metal processing equipment and oil field operations.
Defense u0026 Aerospace
The LCM J1939 Control Module delivers precise operation for complete machine control, military support vehicles and hydraulic systems.