In-Tank / Inline Filters
360 PSI • Up to 400 GPM
Features:
- RF 60 – 330 filters constructed of aluminum material. Aluminum alloy is water tolerant – anodization is not required for high water based fluids (HWBF).
- RF 660 – 1300 filters constructed of ductile iron.
- Non-welded housing design reduces stress concentrations prevents fatigue failure.
- Inlet/outlet port options include NPT, SAE straight thread O-ring boss, and SAE 4-bolt flange to allow easy installation without costly adapters.
- Bolt-on lid requires minimal clearance for removal.
- O-ring seals are used to provide positive, reliable sealing. Choice of O-ring materials (Nitrile, Fluoroelastomer, EPDM) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water base fluids.
- Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.
- Clogging indicators can be serviced without interruption of the hydraulic system.
- Single piece casting provides rigidity for inline or in-tank mounting.
Technical Details
Mounting Method | 4 Mounting holes – filter housing |
Port Connection (Inlet / Outlet) | 60/110: SAE-12 / SAE-12 160/240: SAE-20 / SAE-20 330: 2˝ NPT / 2˝ NPT 2˝ SAE Flange, Code 61 / 2˝ NPT 660: 3˝ SAE Flange, Code 61 / 3˝ NPT 950: 3-1/2˝ SAE Flange, Code 61 1300: 4˝ SAE Flange, Code 61 / |
Flow Direction | Inlet: Side Outlet: Bottom |
Construction Materials Housing, Lid | RF60-330 Aluminum RF660-1300 Ductile Iron |
Flow Capacity | 60: 16 gpm (60 lpm) 110: 29 gpm (110 lpm) 160: 42 gpm (160 lpm) 240: 63 gpm (240 lpm) 330: 87 gpm (330 lpm) 660: 174 gpm (660 lpm) 950: 251 gpm (950 lpm) 1300: 343 gpm (1300 lpm) |
Housing Pressure Rating | Maximum Operating Pressure: 360 psi (25 bar) Proof Pressure: 540 psi (38 bar) Fatigue Pressure: 360 psi (25 bar) @ 700,000 cycles Burst Pressure: 60/110 1080 psi (75 bar) 160/240 1230 psi (85 bar) 330 1440 psi (100 bar) 660-1300 >1440 psi (100 bar) |
Element Collapse Pressure Rating | BN/HC, W/HC, V 250 psid (17 bar) ECO/N, BN/AM, P/HC, AM 145 psid (10 bar) |
Fluid Temperature Range | -22° to 250°F (-30° to 121°C) |
Fluid Compatibility | Compatible with all petroleum oils and synthetic fluids rated for use with Fluoroelastomer or Ethylene Propylene seals. Contact Womack for information on special housing and element constructions available for use with water glycols, oil/water emulsions, and HWBF. |
Indicator Trip Pressure | P = 29 psi (2 bar) – 10% (standard) P = 72 psi (5 bar) – 10% (optional) |
Bypass Valve Cracking Pressure | ΔP = 43 psid (3 bar) + 10% (standard) ΔP = 87 psid (6 bar) + 10% (optional) |